Zákaznícka linka:
0850 111 332
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
1.1 Length
| |||||
1.1.1 | Materialised measures of length | 15 | |||
a) metal | yes | yes | 5 years | ||
b) made of other materials | yes | yes | 2 years | ||
1.1.2 | Length measuring instruments for winding materials (rolling, folding, winding)2) | yes | yes | 2 years | 50 |
1.1.3 | Length measures for checking the folds length of folding measuring machines | no | yes | 5 years | 50 |
1.1.4 | Taximeters of taxi cars | yes | yes | 2 years | 18 |
1.1.5 | Repealed from 30. 10. 2006. | ||||
1.1.6 | Test sieves 2), 9) | no | yes | 2 years | 56 |
1.1.7 | Automatic level gauges 2), 3) | no | yes | 1 year | 68 |
1.1.8 | Multi-dimensional measuring instruments 2), 3) | 13 | after repair 14) | 2 years | 20 |
1.2 Area contents | |||||
1.2.1 | Instruments for measuring the area of leathers 2) | yes | yes | 1 year | 39 |
1.3 Volume, flow rate
| |||||
1.3.1 | Metal volume measures 2) | yes | yes | 2 years | 47 |
1.3.2 | Capacity serving measures 2) | yes | yes | no limit | 27 |
1.3.3 | Serving dispensers 2) | yes | yes | 2 years | 28 |
1.3.4 | Volumetric glass containers, volumetric flasks, burettes, pipettes, volumetric cylinders of accuracy class "A") 2), 3) | yes | yes | no limit | 55 |
1.3.5 | Repealed from 1. 1. 2005 | ||||
1.3.6 | Transport barrels made of non corrosive materials, shape-stable (KEG, KEG Plus, ...) 2) | yes | yes | 10 years | 34 |
1.3.7 | Transport barrels except of those specified in 1.3.6 2) | yes | yes | 2 years | 34 |
1.3.8 | Transport tanks for liquids 2) | ||||
a) Cisterns - tankers | yes | yes | 4 years | 34 | |
b) Volumetric tanks on ships | no | yes | 12 years | 21 | |
1.3.9 | Fixed storage tanks used as volume measures 2), 3) | 48 | |||
a) Cooling and storage milk tanks | no | yes | 4 years | ||
b) Wood barrels and tanks | no | yes | 5 years | ||
c) Concrete and walled storage tanks | no | yes | no limit | ||
d) Barrels and tanks made of other materials | no | yes | 10 years | ||
1.3.10 | Dosing volume measures for liquids 2) | yes | yes | 5 years | 58 |
1.3.11 | Volume measures for alcohol 2), 3), 6) | yes | yes | 3 years | 24 |
1.3.12 | Volume flow meters for liquids other than water | yes | yes | 2 years | 10, 11 |
1.3.13 | Measuring systems | 12 | |||
a) for liquids other than water 2) | yes | yes | 2 years | ||
b) for liquefied gases2) | yes | yes | 1 year | ||
1.3.14 | Mass flow meters for liquids 2) | yes | yes | 2 years | 65 |
1.3.15 | Water meters 2) | ||||
a) for cold water | yes 11) | yes | 6 years | 8 | |
b) for hot water | yes 12) | yes | 4 years | 9 | |
1.3.16 | Conversion devices for quantities of liquids including attached transducers :2) | yes | yes | 2 years | 69 |
a) flow rate transducers | yes | yes | 2 years | 10, 11, 12, 65 | |
b) temperature transducers | yes | yes | 2 years | 37 | |
c) pressure transducers | yes | yes | 2 years | 33 | |
d) density transducers | yes | yes | 2 years | 71 | |
1.3.17 | Diaphragm gas meters incl. gas meters with temperature correction 2) | 13 | |||
a) up to G6 incl., provided, the average year consumption does not exceed 500 m3 | yes | yes | 15 years | ||
b) other diaphragm gas meters | yes | yes | 10 years | ||
1.3.18 | Rotary and turbine gas meters 2) | yes | yes | 5 years | 13 |
1.3.19 | Mass flow meters for gases 2) | yes | yes | 2 years | 66 |
1.3.21 | Gas volume conversion devices incl. attached transducers 2) that are subject to the annual tests on site as specified in Annex No. 35 | yes | yes | 5 years | 35 |
1.3.22 | Water meters for open water levels | according to Annex 64 | yes | 2 years | 64 |
1.3.23 | Packages of the pre-packaged products classified as measuring containers 8) | no | no | - | Ordinance No 207/2000 Coll. as amended by Ord. No 420/2001 Coll. |
1.3.24 | Measuring systems for alcohol 2), 3) | according to Annex | according to Annex | 1 year | 72 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
2.1 Mass
| |||||
Before putting on the market or in use, the measuring instruments specified in the items 2.1.1 to 2.1.4 are subject to the conformity assessment in accordance with the special rule 13) and to the subsequent verification during the time of use. After a repair, they shall be initially verified. | |||||
2.1.1 | Non-automatic weighing instruments of accuracy classes II, III and IIII except of those specified in the items 2.1.2, 2.1.3 a 2.1.4 2), 3), 7) | - | after repair 14) | 2 years | 15 |
2.1.2 | Non-automatic weighing instruments for measuring the axle or wheel loads of railway or road vehicles in the static mode 3) | ||||
a) road | after repair 14) | 1 year | 15) | ||
b) rail way | after repair 14) | 2 years | 15) | ||
2.1.3 | Non-automatic weighing instruments of accuracy classes I and II for weighing precious metals, gemstones and precious materials used in health service 2), 3) | after repair 14) | 2 years | 15) | |
2.1.4 | Non-automatic weighing instruments for counting pieces and for determination of substances properties 2), 7) | after repair 14) | 2 years | 15) | |
2.1.5 | Weights of accuracy classes 1., 2. and 3. 2), 3) | no | yes | 1 year | 17 |
2.1.6 | Weights of accuracy class 4. 2), 3) | no | yes | 2 years | 17 |
2.1.7 | Weights of accuracy class 5. 2), 3) | no | yes | 2 years | 17 |
2.1.8 | Automatic weighing instruments for weighing road vehicles in motion of the accuracy classes 0, 2; 0, 5; 1 a 2, 2), 3) | yes | yes | 1 year | 30 |
2.1.9 | Automatic rail-weighbridges of accuracy classes 0, 2; 0, 5; 1 and 2), 3) | yes | yes | 2 years | 46 |
2.1.10 | Automatic discontinuous totalizing instruments of accuracy classes 0, 2; 0, 5; 1 and 22) | yes | yes | 2 years | 29 |
2.1.11 | Automatic filling instruments 2) | yes | yes | 2 years | 26 |
2.1.12 | Automatic catchweighing instruments 2) | yes | yes | 2 years | 7 |
2.1.13 | Continuous totalizing automatic weighing instruments (belt weighers) of accuracy classes 0, 5; 1 and 2, 2) | yes | yes | 2 years | 6 |
2.1.14 | Cereal testers 2) | yes | yes | 2 years | 20 |
2.2 Mechanical motion
| |||||
Before putting on the market, the measuring instruments in the item 2.2.2 are subject to the type approval according to the special rule. 5) The measuring instruments in the item 2.2.2 that meet the specified requirements at the verification shall be marked by the verification and sealing marks. | |||||
2.2.1 | Road speedometers (used for checking the observance of the rules of the road) 3) | yes | yes | 1 year | 31 |
2.2.2 | Recording equipment used in road traffic 2), 3), 5) | - | yes 5) | 2 years | 5) |
2.3 Pressure
| |||||
Before putting on the market or in use, the measuring instruments specified in the item 2.3.1 are subject to the conformity assessment in accordance with the special rule 13) and to the subsequent verification during the time of use. After a repair, they shall be initially verified. | |||||
2.3.1 | Non-invasive blood pressure gauges 4) | ||||
a) mechanical | after repair 14) | 2 years | 4016) | ||
b) electromechanical | after repair 14) | year | 4016) | ||
2.3.2 | Pressure transducers used in rendering plants 3) | yes | yes | 1 year | 33 |
2.3.3 | Tire pressure gauges for motor vehicles used in fuel pump stations, motor car repair shops, tire services and in vehicle inspection stations | yes | yes | 1 year | 19 |
2.4 Mechanical material tests
| |||||
2.4.1 | Tensile testing machines and presses 2), 3) | no | yes | 2 years | 61 |
2.4.2 | Pendulum impact machines for testing the notch and blow toughness 2), 3 | no | yes | 2 years | 61 |
2.4.3 | Machines for testing the material tensile creeping 2), 3) | 61 | |||
a) using the lever loading machine and direct loading | no | yes | 5 years | ||
b) using the spring or another loading machine | no | yes | 2 years | ||
2.4.4 | Durometers for concrete 3), 10) | no | yes | 1 year | 63 |
2.4.5 | Tensioning equipment for pre-stressed concrete 3) | no | yes | 1 year | 60 |
2.4.6 | Torque wrenches | yes | yes | 1 year | 59 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
3.1 Temperature, heat
| |||||
Before putting on the market or in use, the measuring instruments specified in the item 3.1.1 are subject to the conformity assessment in accordance with the special rule 13) and to the subsequent verification during the time of use. After a repair, they shall be initially verified. | |||||
3.1.1 | Electronic clinical and veterinary thermometers 4) | - | after repair 14) | 2 years | 3217) |
3.1.2 | Instruments used for determination of combustion heat values for purpose of balance measurements 2), 3) | ||||
a) thermometers in glass | yes | yes | 2 years | 38 | |
b) electric temperature sensors | yes | yes | 2 years | 37 | |
c) heat transducers | yes | yes | 2 years | 37 | |
3.1.3 | Thermometers used in volumetric alcoholmeters 2), 3) | yes | yes | 3 years | 38 |
3.1.4 | Heat transducers used in rendering plants 3) | yes | yes | 1 year | 37 |
3.1.5 | Heat meters and their parts 2) | 51 | |||
a) compact heat meters | yes | yes | 4 years | 51 | |
b) flowrate meters | yes | yes | 4 years | 53 | |
c) resistance temperature sensors | yes | yes | 4 years | 37 | |
d) electronic calorimeters | yes | yes | 4 years | 51 | |
e) pressure transducers | yes | yes | 2 years | 33 | |
f) temperature transducers | yes | yes | 2 years | 37 | |
3.1.6 | Combined temperature sensors intended for use in nuclear power plants of VVER 440 type | yes | yes | 1 year | 54 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
4.1 | Single and multi-phase AC dynamic (inductive)electrical energy meters (including two-rate ones) for the direct measurement of the electrical energy consumption 2) | yes | yes | 16 years | 14 |
4.2 | Single and multi-phase AC dynamic (inductive)electrical energy meters for the indirect (connected via transformers) measurement of the electrical energy consumption 2) | yes | yes | 12 years | 14 |
4.3 | AC dynamic (inductive) electrical energy meters with a mechanical additional device for measuring the overconsumption, maximum, and multi-rate electrical energy meters | yes | yes | 12 years | 14 |
4.4 | Single and multi-phase AC static electrical energy meters with electronic measuring system 2) | yes | yes | 12 years | 14 |
4.5 | AC static electrical energy meters or AC dynamic (inductive) meters with an electronic additional device for measuring the overconsumption, maximum, and multi-rate electrical energy meters 2) | yes | yes | 5 years | 14 |
4.6 | Measuring current and voltage transformers used in connection with electrical energy meters 2) | yes | yes | no limit | 52 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
5.1 Light quantities
| |||||
5.1.1 | Luxmeters with silicon photodetector 3) | no | yes | 2 years | 57 |
5.1.2 | Luxmeters with selenium photodetector 3) | no | yes | 1 year | 57 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
6.1 Acoustic pressure
| |||||
Before putting on the market or in use, the measuring instruments specified in the item 6.1.3 are subject to the conformity assessment in accordance with the special rule 13) and to the subsequent verification during the time of use. After a repair, they shall be initially verified. | |||||
6.1.1 | Sound-level meters and integrating sound-level meters 3) | yes | yes | 2 years | 42 |
6.1.2 | Band-pass filters 3) | yes | yes | 2 years | 42 |
6.1.3 | Tone audiometers 4) | - | after repair 14) | 2 years | 4418) |
6.1.4 | Measuring microphones 3) | yes | yes | 1 year | 49 |
6.1.5 | Personal sound exposure meters 3) | yes | yes | 2 years | 42 |
6.1.6 | Sound calibrators 3), 4) | yes | yes | 1 year | 45 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
7.1 Density
| |||||
7.1.1 | Laboratory densimeters with scale interval of < 1 kg. m-3 except of densimeters for measuring soils graiding (Casagrande) 2), 3) | yes | yes | no limit | 70 |
7.1.2 | Laboratory alcoholmeters with scale interval < 0, 2 % 2), 3) | yes | yes | no limit | 16 |
7.1.3 | Laboratory saccharimeters with scale interval 0, 1 % 2), 3) | yes | yes | no limit | 70 |
7.1.4 | Laboratory mustmeters with scale interval 0, 2 kg. hl-1 2), 3) | yes | yes | no limit | 70 |
7.1.5 | Vibration densimeters for liquids and gases 2), 3) | yes | yes | 1 year | 71 |
7.2 Refractivity index (refractometry)
| |||||
7.2.1 | Visual prismatic refractometers with the maximum permissible error of refractivity index in order of 10-4 2), 3) | no | yes | 2 years | 67 |
7.2.2 | Visual prismatic refractometers with the maximum permissible error of refractivity index in order of 10-5 2), 3) | no | yes | 3 years | 67 |
7.2.3 | Digital prismatic refractometers with the maximum permissible error of refractivity index in order of 10-4 and 10-5 2), 3) ) | yes | yes | 2 years | 67 |
7.4 Humidity of solid materials
| |||||
7.4.1 | Moisture meters for cereal grains and oil seeds of accuracy class I. 2) | yes | yes | 1 year | 36 |
7.5 Chemical composition
| |||||
7.5.1 | Analysers of exhaust emissions of vehicles equipped with ignition engines 3) | yes | yes | 1 year | 23 |
7.5.2 | Breath analysers 3) | yes | yes | 1 year except of breath analysers based on the electrochemical principle and of breath analysers put on the market before 31. 12. 2000 - in those cases the verification is valid for 6 months | 25 |
7.5.3 | Gas chromatographs for measuring the energy value of the natural gas 2) | yes | yes | 1 year | 73 |
Item | Kind of measuring instrument - field of measurement | Type approval | Initial verification | Validity of verification | Annex No. |
Meradlá uvedené v položkách 8.2, 8.3, 8.4 a 8.9 podliehajú pred uvedením na trh alebo do používania posúdeniu zhody podľa osobitného predpisu13) a počas používania následnému overeniu. Po oprave podliehajú prvotnému overeniu. | |||||
8.1 | Before putting on the market or in use, the measuring instruments specified in the items 8.2, 8.3, 8.4 and 8.9 are subject to the conformity assessment in accordance with the special rule 13) and to the subsequent verification during the time of use. After a repair, they shall be initially verified. | yes | yes | 2 years | 4319) |
8.2 | Instruments for measuring the activity of diagnostic and therapeutic preparations applied in vivo 3), 4) | - | after repair 14) | 1 year | 4319) |
8.3 | Measuring instruments for determination of the therapeutically absorbed doses of ionizing radiation applied to patients 3), 4) | - | after repair 14) | 1 year | 4119) |
8.4 | Instruments for measuring the radio contamination inside the bodies of contaminated persons 3), 4) | - | after repair 14) | 2 years | 4319) |
8.5 | Instruments for measuring the volume activity of radon 222 in air and in water, and for measuring the equivalent volume activity of radon 222 in air 3) | no | yes | 1 year | 4319) |
8.6 | Systems for measuring the dosimetric quantities used in personal dosimetry 3) | yes | yes | 1 year | 4119) |
8.7 | Measuring instruments and systems for measuring the quantities of the radioactive transformation and of dosimetric quantities, used for monitoring the observation of limits in the field of the radiation protection or safety and for evidential measurements within the radiation monitoring 3) | yes | yes | 2 years | 4119), 4319) |
8.8 | Direct reading personal dosimeters and personal dosimeters signalizing the preset level of dosimetric quantities that are not used simultaneously with the legally controlled measuring instruments specified in the item 8.6 3) | yes | yes | 2 years | 4119) |
8.9 | Instruments for measuring the quality of X-ray beams and sources of X-radiation 3), 4) | - | after repair 14) | 2 years | 4119) |
8.10 | Stationary measuring instruments used for detection of the hidden radioactivity in the passenger traffic and freight transport | no | yes | 2 years | 4319) |